Tensiometer TransducersClick the image thumbnails for full size
Click the image thumbnails for full size
GT3 Jet fill Tensiometer TransducersThe vacuum inside the tensiometer is measured by a pressure transducer, which gives a continuous analogue output signal. A resolution of 0.1 kPa (1 cm H2O) can be attained for the GT3 Tensiometer Transducer.Available models:
GT3-420 Jet fill Tensiometer TransducersThe GT3-420 has an industry-standard 4 to 20mA current loop output that can be used to interface it to a wide variety of standard devices including programmable logic controllers (PLCs) and data loggers. Tensiometer & Pressure Transducer InterfacesThe interface is necessary to connect the tensiometers to the smart logger. Available models:
Request Quote | Specification Sheet
GT3-15 0 to -100 kPa Jet fill Tensiometer TransducersTransducer connection
Ordering Information
Note: Customers requiring cable lengths greater than 1 m are requested to source cable locally. Standard 4 wire cable is required.
Request Quote | Specification Sheet
GT3-30 -100 to 200 kPa Jet fill Tensiometer TransducersTransducer connection
Ordering Information
Note: Customers requiring cable lengths greater than 1 m are requested to source cable locally. Standard 4 wire cable is required.
Request Quote | Specification Sheet
GT3-1 Custom Tensiometer TransducersTransducer connection
Ordering Information
Note: Customers requiring cable lengths greater than 1 m are requested to source cable locally. Standard 4 wire cable is required.
Request Quote | Specification Sheet
GT3-420 Jet fill Tensiometer TransducersThe GT3-420 has an industry-standard 4 to 20mA current loop output that can be used to interface it to a wide variety of standard devices including programmable logic controllers (PLCs) and data loggers. Measuring PrincipleThe soil water tension is transmitted via the ceramic cup into the tensiometer. The vacuum inside the tensiometer is measured by a pressure transducer, which gives a continuous analogue output signal.Resolution and AccuracyA resolution of 0.1 kPa (1 cm H2O) can be attained for the GT3 Tensiometer Transducer. The accuracy actually obtained is related to the calibration and resolution of the analogue to digital converter. In field applications the values obtained should consider the shaft/cup length of the tensiometer: 1 cm = 0.1 kPa.Ordering Information
Notes:
Request Quote | Specification Sheet
Tensiometer & Pressure Transducer InterfacesNote: Customers must specify which pressure transducer type is to be connected to the ST1-B. A transducer specific calibration is required as the response of each of the 1 PSI, 15 PSI or 30 PSI Vacuum Transducers is different in sensitivity of PSI to mV. This correct calibration curve must be known to accurately convert the raw output to kPa.
More Information
Measuring PrincipleThe soil water tension is transmitted via the ceramic cup into the tensiometer. The vacuum inside the tensiometer is measured by a pressure transducer, which gives a continuous analogue output signal. Resolution and AccuracyA resolution of 0.1 kPa (1 cm H2O) can be attained for the GT3 Tensiometer Transducer. The accuracy actually obtained is related to the calibration and resolution of the AD converter. In field applications the values obtained should consider the shaft/cup length of the tensiometer: 1 cm = 0.1 kPa.
System Resolution - General Notes
Transducer Output - General Notes
Transducer Offset and Interface Autozero FunctionVacuum Transducers have an offset in them. This can be taken out by using the autozero function in the Smart Interface (ST1-A or ST1-B) in order to bring it back to zero. Note: Calibrated units (i.e. those with kPa output [ST1-B]) must be used only with the specific transducer with which the electronics were calibrated. Failure to do so will result in an error that may be quite significant.
Links and Brochures
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||