Request Quote | Specification sheet | References

KD-2 and KD-2 Pro Thermal Properties Analyzers

Designed by Decagon, a leading US instrumentation manufacturer, the pocket-sized KD2 thermal properties analyzer uses a single sensor to measure thermal conductivity and thermal resistivity. It uses a simple yet precise heating and monitoring system to measure the slope and intercept of the sample specific temperature rise vs. time curve. The KD2 uses this data to calculate and display thermal conductivity in 90 seconds.

The KD2 only weighs 4 ounces and is very durable, making it ideal for carrying from site to site. The small needle size results in very little compaction during installation and allows for a short heating time -- minimizing thermally induced drying around the probe.

KD-2 Pro

The KD2 Pro uses 3 thermal properties sensors to measure thermal diffusivity, specific heat, thermal conductivity and thermal resistivity. The KD2 Pro allows the user to choose an automated mode where the reading is displayed directly or a manual mode where you can download the raw values from each reading for further analysis using a spreadsheet program as required by IEEE and ASTM standards.

Measurement and Analysis

The KD2 Pro uses transient line heat source method to make measurements. A measurement cycle consists of a 30s equilibration time, a 30s heat time and a 30s cool time. Temperature measurements are made at 1s intervals during heating and cooling. Measurements are then fit with exponential integral functions using a nonlinear least squares procedure. A linear drift term corrects for temperature changes of the sample during the measurement, to optimize the accuracy of the readings.

Specifications

  KD-2 KD-2 Pro
Measurement time 90 seconds 2 minutes
Accuracy 5% Thermal conductivity/Resistivity

5% specific heat
5% Thermal conductivity/Resistivity
10% Thermal Diffusivity

Range of Measurement

K: 0.02 to 2 Wm-1 C-1
R: 0.5 to 50mC W-1

K: 0.02 to 2 Wm-1 C-1
D: 0.1 to 1.0 mm2s-1
R: 0.5 to 50mC W-1
C: 0.5 to 4 MJ m-3 C-1

Operating Environment -10°C to 60°C -50°C to 150°C
Weight 0.613 kg 0.95 kg
Power 3V Lithium CR2 battery 4 x 'AA' batteries
  • The use of Arctic Silver thermal paste is recommended for making measurements via an access tube such as in concrete, etc.

Related Document Downloads

KD2 Brochure 1.7M PDF
KD2 Pro Brochure 222K PDF
KD2 User Manual 132K PDF
KD2 Pro User Manual 851K PDF
KD2 Application Notes
Application Note: Underground Power Cable Installations: Soil Thermal Resistivity 34K PDF
Application Note: The KD2 Thermal Properties Analyzer vs. Published Standards 121K PDF
Application Note: Thermal Resistivity of Soils change with changes in... 97K PDF
Application Note: Thermal Properties of Selected Foods using a Dual-Needle Heat-Pulse Sensor. 108K PDF

 

 



Quick Links: