|
Hukseflux Thermal Sensors Products Directory
Hukseflux specialises in heat flux and thermal conductivity measurement.
- Thermal conductivity measurement
- Heat flux measurement
- Radiation measurement
FTN01
Field thermal needle system for thermal resistivity/ conductivity measurement
The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.
|
|
MTN01
Multi-purpose thermal needle system for thermal resistivity/ conductivity measurement
The MTN01 Multi-purpose Thermal Needle System allows performing fast measurements of the thermal resistivity or conductivity of soils. It is specifically designed to be reasonably robust, as well as accurate. It is therefore suitable for laboratory as well as field- measurements of soil thermal properties.
The sensor is a Non-Steady-State Probe (NSSP), TP07, which is mounted on the Insertion Tool, IT02. The system is operated using a hand-held Control and Readout Unit CRU01.
|
|
TP02
Non-steady-state probe for thermal conductivity measurement
TP02 is a probe that offers the possibility to perform a practical and fast measurement of the thermal
conductivity (or thermal resistivity) of the medium in which it is inserted at the highest accuracy level.
It works in compliance with the ASTM D 5334-00, D 5930-97 and IEEE 442-1981 standards. The
standard TP02 probe has proven suitability in soils, thermal backfill materials, sediments,
powders, sludges, paints, glues and various other materials. The Non-Steady-State Probe (NSSP)
measurement method (also known as transient line source, thermal needle, hot needle, heat pulse and
hot wire technique) has the fundamental advantages that it is fast and absolute while the sample size is
not critical.
|
|
CRC Series
Calibration reference cylinders for thermal needle probes TP02/TP08, TP07 and TP09
CRC′s contain traceable thermal conductivity reference materials for calibration of Non-Steady-State Probes. There are several different CRC types. The geometry of the different types is adapted to fit needles with a certain diameter.
Hukseflux is a leading supplier of Non-Steady-State Probes, and is the inventor of the CRC calibration method.
|
|
NR01
4-Component Net Radiation Sensor
NR01 is a 4-component net-radiation sensor that is used
for scientific grade energy balance studies. The
instrument has separate measurements of solar (Short
Wave or SW) and Far Infra-Red (Long Wave or LW)
radiation.
Major improvements relative to comparable instruments
include weight (reduced), solar offsets in the LW signal
(reduced), ease of leveling (high, because leveling
assembly is included).
|
|
© 2003-2009, ICT International
EST NSW Australia
|