GT3-420 Jet fill Tensiometer Transducers![]() Measuring PrincipleThe soil water tension is transmitted via the ceramic cup into the tensiometer. The vacuum inside the tensiometer is measured by a pressure transducer, which gives a continuous analogue output signal. Resolution and AccuracyA resolution of 0.1 kPa (1 cm H2O) can be attained for the GT3 Tensiometer Transducer. The accuracy actually obtained is related to the calibration and resolution of the AD converter. In field applications the values obtained should consider the shaft/cup length of the tensiometer: 1 cm = 0.1 kPa. The GT3-420 has an industry-standard 4 to 20mA current loop output that can be used to interface it to a wide variety of standard devices including programmable logic controllers (PLCs) and data loggers. Ordering Information
Note: Customers requiring cable lengths greater than 1 m are requested to source cable locally. Standard 4 wire cable is required.